The Model GIR912 has been replaced by Model GIR914.
GIR912 NOVA-Sensor Elite™ Carbon Dioxide Gas Detector Use the NOVA-Sensor Carbon Dioxide Gas Detector to alert personnel when lifethreatening CO2 is present in a protected area. This detector uses the non-dispersive infrared (NDIR) principle to detect and monitor the presence of gas. The display screen on the NOVA-Sensor continuously displays operating status and the actual percentage of CO2.
Use the NOVA-Sensor Carbon Dioxide Gas Detector to alert personnel when lifethreatening CO2 is present in a protected area. This detector uses the non-dispersive infrared (NDIR) principle to detect and monitor the presence of gas. The display screen on the NOVA-Sensor continuously displays operating status and the actual percentage of CO2. This reading is converted to a standard 4-20 mA signal, which may be connected to any remote device for remote display or logging. Relay contacts are provided which transfer when the gas concentration exceeds the LOW ALARM and HIGH ALARM set points. Typical set points are adjusted by the installer upon installation and may be reset later by authorized personnel. The relays are suitable for controlling local HVAC equipment, alarm signal devices or for equipment shutdown. Fault relay contacts are also available which operate upon loss of power or internal failure of the unit. The calibration verification or test sequence is initiated by depressing the pushbutton switch located on the side of the enclosure. During calibration/test, step-bystep instructions are displayed on the NOVA-Sensor screen. There are no screwdriver or other manual adjustments required, and the calibration can be performed even in the presence of combustible gases. The GIR912 is available in versions to operate in the ranges of 2% to 100% CO2 by volume.
Power Input: | 24 volts DC nominal, 180 mA standby, 240 mA alarm Will operate within specifications at any supply voltage between 16 and 32 volts. |
Measuring Range: | 0-2%, 0-5%, 0-30% or 0-100% by volume Carbon Dioxide |
Signal Output: | 4 mA @ 0% CO2, 20 mA @ full scale CO2 |
Resolution: | 2% of full scale |
Operating Temperature: | +14 to +122° F (-10 to +50° C) |
Ingress Protection: | IP40 to IP66 Depends on installed protection options |
Signal Output: | 0.16 mA per % LEL Automatically adjusted during calibration |
Resolution: | 2% LEL |
Repeatability: | Zero: ±0.1% of full scale Signal: ±0.05% of full scale |
Warm-up Time: | 10 seconds after power applied |
T90 Response Time: | Less than 30 seconds |
Maintenance Interval: | 6 months For verification of performance only |
Relay Outputs: | Low Alarm (latching or nonlatching) High Alarm (latching) Malfunction (non-latching) |
Relay Contact Ratings: | 6 amps @ 28 VDC or 300 VAC resistive 1/8 HP @ 120/240 VAC |
Analog Output: | 0 to 20 mA into a load of 600 ohms or less |
Size: | 7 x 12 inches, 5 inches deep (178 x 305 x 127 mm) Includes junction box and sensor. Conduit connection is ¾ inch NPT thread. |
Weight: | 6.75 pounds (3.06 kg) |